  • Manufacturer: Venmar Ventilation ULC
  • Model Series: vanEE AI Series
  • Model Description: 6” TOP Ports HRV
  • Ventilation Performance: 150 cfm @0.4 in. wg
  • Manufacturers’ Part Number: V160H75RT
  • Venmar AVS Equivalent Part Number: A160H75RT
  • Wall Controller Included: none ***
  • Core Type: Heat Recovery Ventilator (HRV)
  • Defrost Type: Damper Defrost (Includes Recirculation)
  • Motor Type: ECM PMSM (High Efficiency)
  • Heat Recovery Rate (SRE) : 75 %  
  • Moisture Transfer rate: 0 %

Purchase Includes Unlimited Technical Support.

Canada-Wide shipping  ( 1-5 day delivery on most orders )

(see shipping estimates in shopping cart)

Ships in : 2 – 5 Days

Our Order Number: AI-103

 

Price: $998.00

In stock

Quantity:
SKU: AI-103 Categories: , Tag:

A NEW ERA FOR AIR EXCHANGERS, DRIVEN BY VIRTUO AIR TECHNOLOGY

Introducing the industry’s most advanced residential air exchanger, created to offer you much more than a standard Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV). The AI Series features a universal platform that works with every conceivable type of dwelling, simplifying the installation while delivering superior air quality and comes standard with Virtuo Air Technology.

Consumer Video – Click Here                             Contractor Video – Click Here

New Controls Video – Click Here                       Installation Video – Click Here

VIRTUO AIR TECHNOLOGY

Introducing Virtuo Air TechnologyTM, the first air exchanger artificial intelligence that allows the airflow verification, the auto-balancing and self-adjusting to changing indoor and outdoor conditions.

With Virtuo, you can rely on a smart algorithm to ensure optimal indoor air quality. When a pressure change occurs, Virtuo detects it and instantly adjusts the air exchanger’s operation to consistently deliver the proper amount of fresh air with minimal energy consumption. Staying 100% balanced. Always!

Venmar New Models Summary Sheet

vanEE AI Series V160H spec sheet (English)

vanEE AI Series Venmar AVS N Series Installation Manual

vanEE AI series Venmar AVS N series maintenance instructions

 

  • Manufacturer: Venmar Ventilation ULC
  • Model Series: vanEE AI Series
  • Model Description: 6” TOP Ports HRV
  • Ventilation Performance: 150 cfm @0.4 in. wg
  • Manufacturers’ Part Number: V160H75RT
  • Wall Controller Included: none ***
  • Core Type: Heat Recovery Ventilator (HRV)
  • Defrost Type: Damper Defrost (Includes Recirculation)
  • Motor Type: ECM PMSM (High Efficiency)
  • Heat Recovery Rate (SRE) : 75 %  
  • Moisture Transfer rate: 0 %

AIR EXCHANGER NEW INSTALLATION    $598.00

(Greater Toronto Area) 

GasExperts™  Air Exchanger Retrofit Installation Service Notes:
  • Two 6″ holes will be cut to your home’s exterior wall for the new weatherhoods.
  • Installation Method = “Simplified” (furnace return duct method).
  • Installation fee includes proper furnace / HRV interlock setup.
  • Typical installations will include two certified HVAC technicians.
  • Installation fee includes proper airflow adjustments & accurate air balancing.
  • Main or Auxiliary control wiring to upper level may incur additional fee’s.
  • Upon Completion of install, full maintenance & operating instructions provided.
  • Installation includes a 30-Day Money-Back Satisfaction Guarantee.
 ACCESSORIES FEE: $165.00
  • Accessories fee includes properly sized ducting for the recommended air flows.
  • Accessories fee includes up to 25 feet of insulated duct.
  • Accessories fee includes up to 25 feet of non-insulated duct.
  • Accessories fee includes two fixed covered intake & exhaust hoods with mesh

AIR EXCHANGER REPLACEMENT SERVICE    $348.00

(Greater Toronto Area) 

  • Typical installations will include one certified HVAC technician.
  • Installation fee includes proper airflow adjustments & accurate air balancing.
  • Accessories fee (if any)  to be determined upon arrival.
  • Wall or Auxiliary control wiring to upper level may incur additional fee’s.
  • Upon Completion of install, full maintenance & operating instructions provided

AIR EXCHANGER MAINTENANCE VISIT  $96.00

(Greater Toronto Area)

We have you covered with our 13-Point comprehensive maintenance package:
  • Remove and clean filters. Vacuum / wash or replace* worn out filters as necessary.
  • Remove and clean heat core. Vacuum / wash as necessary.
  • Clean interior housing and motor fan blades. Vacuum and wipe clean as necessary.
  • Clean the drain line, flush if necessary. Ensure drain trap is properly working. Replacement of broken fittings or blocked drain lines*
  • Inspect and clean all interior grilles.
  • Inspect and clean exterior weather hoods. Replacement of broken / missing screens. Re-caulk / seal with foam where necessary. replacement of damaged or inferior exterior hoods as necessary*
  • Check defrost damper and cold air sensor. Confirm the damper opens, closes and seals properly.
  • Inspect insulated flexible duct and reseal where necessary. If insulated duct is wet and soggy, replacement will be advised*
  • Inspect non-insulated duct and seal with foil tape where necessary.
  • Ensure furnace interlock is working properly. Re-wire if necessary.
  • Ensure if installed that the spring-loaded back draft damper is operating properly. (typically located on the “stale air to outside collar”).  Install new damper if required*
  • Check wall control to ensure proper operation of HRV.
  • Most importantly, measure and properly balance HRV air flows as required by specific HRV manufacturer.